Overhead Tank Water Level Controller Dol Starter Based Motor Drive For Single Pump
Specifications:
MODEL NO | OHDOL1/23 |
Control on | Overhead Tank |
Facia Indications | Power on/Pump on Overhead tank level status |
Protections | Overhead tank Empty |
Operation Mode | Auto / Manual |
Pump | Single Phase / Three Phase motor with starter/contactor |
Pump Selection | Single Pump |
Supportable Sensors | Float/Magnetic/ SS electrode |
Supply Voltage | 230V AC/50 Hz |
Sensing Voltage | 12V DC/0.12 Micro Amp |
Size | W X H X D 4.75 X 8 X 2.5 inch |
Mounting | Wall mounted type |
Cabinet | MS powder coated |
Assembling | Industrial grade components |
Overhead Tank Water Level Controller Direct Motor Drive
This model is suitable where overhead tank capacity is small and underground tank capacity is large.
This controller is suitable for controlling the overhead tank water supply as soon as the overhead tank gets empty. The pump will start and the underground tank water will be transferred to overhead tank. The pump will be stop when the overhead tank gets full.
Note: if water is supply from underground tank & incoming water flow will be very high ball valve required to stop underground tank overflow.
Overhead Tank Water Level Controller With Dry Run Protection Direct Motor Drive
Specifications:
MODEL NO | OHDMCDR/23/30AMP |
Control on | Overhead Tank |
Facia Indications | Power on/Pump on/Motor Dry Run Overhead tank level status |
Protections | Overhead tank Full Motor Dry Run |
Dry Run Protection Time and control | 20 to 60 Seconds /Local Dry run Audio Alarm and motor trip automatically, Reset switch to restore the motor operation subject to clearance of Dry run |
Operation Mode | Auto / Manual |
Pump | Single Phase pump Up to 2 Hp Direct Drive |
Pump Selection | Single Pump |
Supportable Sensors | Float/Magnetic/ SS electrode |
Supply Voltage | 230V AC/50 Hz |
Sensing Voltage | 12V DC/0.12 Micro Amp |
Size | W X H X D 6 X 8 X 2.5 inch |
Mounting | Wall mounted type |
Cabinet | MS powder coated |
Assembling | Industrial grade components |
Overhead Tank Water Level Controller With Dry Run Protection Dol Starter Based Motor Drive For Single Pump
SPECIFIATIONS:
MODEL NO | OHDOL1DR/23 |
Control on | Overhead Tank |
Facia Indications | Power on/Pump on/Motor Dry Run Overhead tank level status |
Protections | Overhead tank Empty Motor Dry Run |
Dry Run Protection Time and control | 20 to 60 Seconds /Local Dry run Audio Alarm and motor trip automatically, Reset switch to restore the motor operation subject to clearance of Dry run |
Operation Mode | Auto / Manual |
Pump | Single Phase / Three Phase motor with starter/contactor |
Pump Selection | Single Pump |
Supportable Sensors | Float/Magnetic/ SS electrode |
Supply Voltage | 230V AC/50 Hz |
Sensing Voltage | 12V DC/0.12 Micro Amp |
Size | W X H X D 4.75 X 8 X 2.5 inch |
Mounting | Wall mounted type |
Cabinet | MS powder coated |
Assembling | Industrial grade components |